General Product Specifications
| Specification | Detail / Value |
| Product Name | Atlas Aortic Nitinol Stent |
| Intended Use | Endovascular stenting in thoracic or abdominal aorta, typically for aneurysms, dissections, or arterial stenosis |
| Design | Self-expanding nitinol stent with moderate radial force, open-cell or hybrid-cell architecture |
| Material | Medical-grade Nitinol (Nickel-Titanium), shape-memory alloy |
| Deployment Mechanism | Sheath-based release; stent expands upon sheath retraction |
| Delivery System | Over-the-wire (OTW) or integral introducer, typically 14–24F sheath compatibility (depending on stent diameter) |
| Radial Force | Medium to high, ensuring stable apposition to aortic walls |
| Radiopaque Markers | Multiple markers at proximal and distal stent edges for precise fluoroscopic placement |
| MR Compatibility | MR Conditional (check device labeling) |
| Sterility | Sterile (Ethylene Oxide) |
| Single Use | Yes |
| Shelf Life | ~3–5 years if maintained in sealed packaging at 15–25 °C |
| Operating Temperature | 15–25 °C recommended storage |
| Clinical Indications | Thoracic aortic aneurysm (TAA), infrarenal AAA, certain dissections, possible trauma repair |
| Contraindications | Extremely tortuous or heavily calcified aorta preventing safe stent deployment, known nickel allergies |
Detailed Size-Based Ordering & Product Codes
| Diameter (mm) | Length (mm) | Sheath Rec. (F) | Product Code | Notes |
| 20 | 80 | 14F | ATL-NIT-20x80 | Smaller aortic stent, short coverage |
| 20 | 100 | 14F | ATL-NIT-20x100 | |
| 20 | 120 | 14F | ATL-NIT-20x120 | |
| 22 | 80 | 16F | ATL-NIT-22x80 | Slightly bigger diameter, moderate coverage |
| 22 | 120 | 16F | ATL-NIT-22x120 | |
| 22 | 160 | 16F | ATL-NIT-22x160 | Extended length for extended lesions |
| 24 | 100 | 16F | ATL-NIT-24x100 | Common diameter for standard AAA fix |
| 24 | 140 | 16F | ATL-NIT-24x140 | |
| 24 | 160 | 16F | ATL-NIT-24x160 | |
| 26 | 120 | 18F | ATL-NIT-26x120 | Larger diameter stent for wide aortic segments |
| 26 | 160 | 18F | ATL-NIT-26x160 | |
| 28 | 120 | 20F | ATL-NIT-28x120 | |
| 28 | 160 | 20F | ATL-NIT-28x160 | |
| 28 | 180 | 20F | ATL-NIT-28x180 | Extended coverage for big AAA or TAA |
| 30 | 140 | 20F | ATL-NIT-30x140 | |
| 30 | 180 | 20F | ATL-NIT-30x180 | |
| 32 | 140 | 22F | ATL-NIT-32x140 | High diameter for advanced TAA |
| 32 | 180 | 22F | ATL-NIT-32x180 | |
| 34 | 160 | 22F | ATL-NIT-34x160 | |
| 36 | 160 | 22F | ATL-NIT-36x160 | |
| 38 | 180 | 24F | ATL-NIT-38x180 | Very large aorta stent |
| 40 | 200 | 24F | ATL-NIT-40x200 | Max diameter + length for extensive coverage |
Atlas Aort Nitinol Stent, standart aort stent platformlarının erişemediği geniş bir çap ve uzunluk yelpazesi sunan bir endolüminal stent protezidir . Nitinolün şekil hafızası ve süperelastik özelliklerini kullanarak Atlas, aort içinde dayanıklı radyal destek ve hassas yerleştirme sağlamak , damar açıklığını iyileştirmek ve potansiyel olarak endovasküler aort onarımındaki komplikasyonları azaltmak için tasarlanmıştır .
Yüksek Performanslı Nitinol Alaşımı
•Şekil Hafızası ve Süperelastisite : Nitinol bileşimi, tutarlı radyal kuvveti garanti eder , dinamik aort anatomisine sorunsuz bir şekilde uyum sağlar ve kıvrılmaya karşı direnç gösterir.
•Termal Stabilite : Değişen vücut sıcaklıklarında stabil bir stent mimarisinin korunmasını sağlar; bu, aort fiksasyonu ve uzun vadeli performans için gereklidir.
Çok Yönlü Çap ve Uzunluk Seçenekleri
•Stent Çap Aralığı : 14 mm – 40 mm, çeşitli aort boyutlarına uygundur.
•Stent Uzunluk Seçenekleri : 70 mm, 100 mm veya 130 mm— farklı lezyon boyutları veya anevrizmal segmentler için özel endovasküler kaplamaya olanak tanır.
Kablo Üzerinden (OTW) Teslimat Sistemi
•Kılavuz Tel Uyumluluğu : 0,035” standart, aort müdahalelerinde yaygın prosedürel iş akışlarıyla entegrasyonu kolaylaştırır .
•Uygulama Sistemi : Stent çapı ve erişim yeri kısıtlamalarının optimum dengesi için 12 Fr , 14 Fr veya 16 Fr konfigürasyonlarında sunulmaktadır.
100 cm Kullanılabilir Kateter Uzunluğu
•Genişletilmiş Erişim : Kıvrımlı veya uzun segmentler dahil olmak üzere karmaşık aort anatomilerinde sağlam manevra kabiliyeti sağlar.
•Tekdüze Dağıtım Kontrolü : Stentin tutarlı bir şekilde konumlandırılmasını sağlayarak prosedür doğruluğunu ve hasta sonuçlarını iyileştirir