ThermoBLOCK Varicose Vein Radiofrequency Ablation System

A radiofrequency ablation platform for incompetent superficial veins, offering thermal closure of saphenous or perforating veins to relieve varicose symptoms.

Ürün Özellikleri

Şartname Detay / Değer
Ürün Adı ThermoBLOCK Varisli Damar RF Ablasyon Sistemi
Amaçlanan Kullanım Yetersiz safen veya perforatör venlerin endovenöz radyofrekans ablasyonu (RFA)
RF Kateter Tasarımı Distal uca yakın elektrot segmentli 6–7F kateter, sıcaklık kontrollü
Nominal Güç ~10–30 W (damar çapına ve sistem ayarına bağlıdır)
Kateter Uzunluğu ~60–120 cm (koda göre değişir)
Jeneratör Uyumluluğu ThermoBLOCK RF Jeneratörü veya evrensel 460 kHz sistemi
Sıcaklık İzleme Ablasyon segmentinde entegre termokupl
Tedavi Döngüsü Genellikle segment başına ~20–40 saniye, sıcaklık geri bildirimiyle otomatik olarak düzenlenir
Kısırlık Steril, Tek Kullanımlık
Raf ömrü ~15–25 °C'de 2–3 yıl
Klinik Endikasyonlar Büyük safen ven (GSV) reflü, küçük safen ven, perforatör yetersizliği
Kontrendikasyonlar Belirsiz damar anatomisi, şiddetli periferik arter hastalığı, cihaz malzemelerine karşı bilinen intolerans

Sipariş ve Boyut Matrisi

Kateter Boyutu (F) Kateter Uzunluğu (cm) Ablasyon Segmenti (cm) Ürün Kodu Notlar
6F 60 7 TBLK-6F-60-7 Küçük segmentler için kısa kateter
6F 100 7 TBLK-6F-100-7 Standart ablasyon uzunluğu, uzatılmış şaft
7F 100 10 TBLK-7F-100-10 Büyük GSV gövdesi için daha uzun ablasyon segmenti
7F 120 10 TBLK-7F-120-10 Daha uzun boylu hastalar veya daha kapsamlı reflü için
7F 120 15 TBLK-7F-120-15 Büyük gövde damarları için ekstra ablasyon segmenti

The Thermal Coagulation RF Ablation Generator is an advancedfeedback-driven system designed to deliver high-frequency radiofrequency (RF) energy to ThermoBLOCK™ catheters and ThermoBLOCK™ stylets—enabling targeted thermal ablation for chronic venous insufficiency (CVI). Equipped with a real-time monitoring mechanism, the generator precisely regulates intravascular heat parameters, ensuring safe and consistent power application while protecting surrounding tissues.

Real-Time Feedback Control:
•Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
•Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.

Precision RF Delivery:
•Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing and sealing of incompetent veins.
•Minimal Collateral Damage: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.

User-Friendly Interface:
•Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
•Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.

Versatile Integration:
•ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
•Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.

ThermoBLOCK Varicose Vein Radiofrequency Ablation System
Yükleniyor / Loading ...