Ürün Özellikleri
| Şartname | Detay / Değer |
| Ürün Adı | AngioTEN Kapatma Cihazı |
| Amaçlanan Kullanım | Kateterizasyon sonrası perkütan vasküler kapatma |
| Kapatma Mekanizması | Sütür aracılı veya kollajen tıkaç |
| Uygulanabilir Erişim Siteleri | Femoral arter/ven 8F–10F'ye kadar introdüser boyutları |
| Dağıtım Yöntemi | Tek adımda cihaz yerleştirme ve ankraj serbest bırakma |
| Hemostaz Zamanı | Genellikle dağıtımdan sonra < 1 dakika |
| Kısırlık | Steril, Tek Kullanımlık |
| Raf ömrü | ~15–25 °C'de 2–3 yıl |
Sipariş ve Boyut Matrisi
| Erişim Boyutu (F) | Kapatma Yöntemi | Dağıtım Adımları | Ürün Kodu |
| 5–8 | Kolajen Fişi | Bekar | ATN-CP-5-8-S |
| 5–8 | Sütür aracılı | Bekar | ATN-SM-5-8-S |
| 8–10 | Kolajen Fişi | Bekar | ATN-CP-8-10-S |
| 8–10 | Sütür aracılı | Bekar | ATN-SM-8-10-S |
AngioTEN Closure Device by INVAMED is a cyanoacrylate-based closure system designed to seal and stabilize the access site after angiographic procedures. Equipped with a specialized applicator, it ensures precise and user-friendly application of the adhesive over vascular puncture sites, reducing bleeding complications and enhancing patient recovery. By combining rapid polymerization with a biocompatible formula, AngioTEN helps minimize pseudoaneurysm formation and shortens manual compression time—optimizing clinical workflow in catheterization labs.
Cyanoacrylate Adhesive Technology
Employs a fast-curing medical-grade cyanoacrylate that bonds rapidly to tissue edges, helping create a secure and durable seal at the arterial or venous puncture site.
Ergonomic Applicator
Features a slim, intuitive applicator that allows precise dropwise or thin-stripe application, ensuring minimal adhesive wastage and targeted closure even in narrow access points.
Rapid Hemostasis
By instantly sealing the puncture track, AngioTEN reduces the need for prolonged manual compression or adjunct compression devices, potentially improving patient comfort and catheter lab throughput.
Biocompatible & Safe
Formulated to minimize tissue irritation and promote natural healing processes. Ideal for radial or femoral access closure after diagnostic angiography or interventional procedures.
Reduced Risk of Complications
Stabilizing the access site lowers the incidence of hematoma, pseudoaneurysm, or AV fistula formation, supporting safer vascular interventions and quicker discharge protocols.
Contraindications
•Heavy calcification, severely diseased artery walls
•Uncontrolled bleeding or coagulopathy beyond standard care measures
•Infection at the puncture site